Alarm Input/Output Configuration

Application Guide

For relay control and IoT automation examples, see the Relay Control & IoT Automation application guide.

Configure and control hardware alarm inputs (sensors) and outputs (relays). This page covers three endpoints:

  • GetAlarmInConfig -- read alarm input sensor settings
  • GetAlarmOutConfig -- read alarm output relay settings
  • ManualAlarmOut -- manually trigger or release an alarm output relay

GetAlarmInConfig

Retrieves alarm input configuration including sensor name, voltage type, and linked alarm outputs.

FieldValue
Endpoint/GetAlarmInConfig[/channelId]
MethodPOST or GET
ProductsIPC, NVR

Response Example

<?xml version="1.0" encoding="UTF-8"?>
<config version="1.0" xmlns="http://www.ipc.com/ver10">
<types>
<alarmInVoltage>
<enum>NO</enum>
<enum>NC</enum>
</alarmInVoltage>
</types>
<sensor>
<id type="uint32">1</id>
<sensorName type="string" maxLen="11"><![CDATA[Sensor1]]></sensorName>
<switch type="boolean">true</switch>
<voltage type="alarmInVoltage">NO</voltage>
<alarmHoldTime type="uint32">10</alarmHoldTime>
<triggerAlarmOut type="list" count="1">
<itemType type="boolean"></itemType>
<item id="1">true</item>
</triggerAlarmOut>
</sensor>
</config>

Parameters

ParameterTypeDescription
iduint32Sensor input number
sensorNamestring (max 11 chars)User-defined name for this sensor input
switchbooleanEnable or disable this alarm input
voltageenumContact type: NO (normally open) or NC (normally closed)
alarmHoldTimeuint32Duration (seconds) alarm stays active after trigger
triggerAlarmOutlistWhich alarm output relays to activate when this sensor triggers

GetAlarmOutConfig

Retrieves alarm output (relay) configuration.

FieldValue
Endpoint/GetAlarmOutConfig[/channelId]
MethodPOST or GET
ProductsIPC, NVR

ManualAlarmOut

Manually triggers or releases an alarm output (relay). Set status to true to activate or false to deactivate.

FieldValue
Endpoint/ManualAlarmOut[/channelId]
MethodPOST
ProductsIPC, NVR

Request Example

<?xml version="1.0" encoding="UTF-8"?>
<config version="1.0" xmlns="http://www.ipc.com/ver10">
<action>
<status>true</status>
</action>
</config>
ParameterTypeDescription
statusbooleantrue to activate the relay, false to deactivate

Known Issues

Firmware Bug (IPC)

The camera forcibly resets the alarm output when a perimeter alarm cycle ends, even when the alarm output mode is set to manual_alarm and triggerAlarmOut is unchecked. This makes ManualAlarmOut unreliable for automation while perimeter detection is active. If you need reliable relay control alongside AI detection, consider using the NVR's alarm outputs instead, or use an external relay controller (such as an ESP8266) driven by traject data.


Notes

  • On NVR systems, include the channelId to target a specific camera channel's alarm I/O.
  • The voltage setting must match the physical wiring of the connected sensor (normally open vs. normally closed).